Operating Modes

Quick Reference Guide

21

Operating Modes

Scan Mode

The imager can be set to operate in one of several scanning
modes. See the PRG for more information and settings for any
of the options:

Trigger Single (Default):

This mode is associated with typical

handheld reader operation. Motion Sense is active and if the
scanner detects motion the aiming pattern is turned on. When
the trigger is pulled, illumination is turned on and the scanner
attempts to read a label. Scanning is activated until one of the
following occurs:

the programmable “maximum scan on time”

1

has

elapsed

a label has been read

the trigger is released

Trigger Pulse Multiple:

Scanning begins when the trigger is

pulled and continues after the trigger is released, until the trig-
ger is pulled again or until the programmable “maximum scan
on time”

1

has elapsed. Reading a label does not disable scan-

ning. Double Read Timeout

1

prevents undesired multiple

reads while in this mode.

Trigger Hold Multiple :

When the trigger is pulled, scanning

starts and the product scans until the trigger is released or
“maximum scan on time”

1

has elapsed. Reading a label does

not disable scanning. Double Read Timeout

1

prevents unde-

sired multiple reads while in this mode.

Always On:

The illuminator is always ON and the reader is al-

ways ready for code reading. Double Read Timeout

1

prevents

undesired multiple reads.

Flashing:

The reader illuminator flashes on and off regardless

of the trigger status. Code reading takes place only during the
Flash On

2

time. Double Read Timeout

1

prevents undesired

multiple reads.

Object Detection

3

:

The scanner looks for changes within its

field-of-view. The Aiming Pattern is always on to show the op-
timum reading area. If a predefined amount of movement is
detected, the red illumination switches on. Scanning contin-
ues until a label is read or "maximum scan on time" is reached.

1.

See the Product Reference Guide (PRG) for these and other programmable
features

2.

Controlled by Flash On Time and Flash Off Time. Use the PRG to program these
options.

3.

This feature is available starting with firmware release 610001013.