Functional Description—RS 485 Comm. Model

Figure 6: RS485 Control Unit Extension PCB

Pin Listings
The allocation of pins on the main connector, J2, for use with the
RS485 controller model is described below.

Table 17: J2 Pin Listings

The following table describes the connectivity of connector J16,
the RS485 connection, which is located on the extension PCB.

Table 18: J16 Pin Listings

Pin

Signal

Description

Remarks

1

0V DC

Power

2

+24V DC

Power

3

Ground

Ground

4

Not connected

Not connected

5

In 2

Trigger and hold

See

User Manual

6

In 1

Not used

Not used

7

Out 2

Light array interrupted 

0V DC = interrupted

24V DC = not interrupted

8

Out 1

Overhang

24V DC = no overhang

 Or over-height (special function)

Pin

2 Wire

4 Wire

1

0 VDC

0 VDC

2

-

Rx+

3

Shielding

Shielding

4

-

Rx-

5

B

Tx+

6

A

Tx-

PNP

D7 LED - Power

RS485

Extension

PCB

D3 LED Out 1
D4 LED Out 2

D9 Error

D8 Com Tx

D6 LED In 2
D5 LED In 1

RJ45 Connector
Emitter

RJ45 Connector
Receiver

D2 LED
D1 LED

Pot 2

Pot 1

Removable

Spring-Loaded

Connector

S1

J2

J12

J13

S2

Out 1
Out 2
In 1
In 2
n. c.
Earth.
24 VDC
0 VDC

In 2

PNP

NPN
PNP

NPN

In 1

Input
Logic
Jumpers

In 2

PNP

NPN
PNP

NPN

In 1

Input
Logic
Jumpers

The following figure provides additional information on the
impedances associated with each of the RS485 inputs.

Figure 7: Input Schematic of the RS485 Terminal

LED Indicators
The following table describes LED D8 and D9 on the RS485
extension PCB.

Table 19: RS485 Controller LED Status

LED

Description

Color

Meaning

D8

Data communication

Off

No communication

Green flashing

Communication active

D9

RS485 Error

Off

No RS485 error

Red

RS485 error

Advertising