4

Additionally, the CAN and RS485 controller models offer the
flexibility of adjusting these settings through use of specified
commands over the serial interface.

Resetting Default Parameter Settings

All controllers are shipped with default parameter values, that can
be changed through the teach process for the I/O model and
through serial commands for the RS485 and CAN models. The
default parameters can be reset in all models through the
following procedure:

• Turn controller power off.

• Set switch 8 on DIP switch array S1 to ON.

• Turn controller power on.

• Set switch eight on DIP switch array S1 to OFF.

• Default settings should now be restored.

Functional Description—Analog Model

Figure 3: Analog Model

The analog controller model offers either 4…20 mA or 0…10V
(current or voltage selectable via DIP switch) output proportional
to target height, width, or position. The output is automatically
scaled to the length of the connected arrays, so most applications
do not require additional adjustments. A teach button is available
for applications that require customized scaling of the output.

In 2

PNP

NPN
PNP

NPN

D7 LED - Power

Analog

Extension

PCB

D3 LED Out 1
D4 LED Out 2
D6 LED In 2
D5 LED In 1

D13 LED

D15 LED

D12 LED
D11 LED
D10 LED

RJ45 Connector
Emitter

RJ45 Connector
Receiver

D2 LED
D1 LED

In 1

Pot 2

Pot 1

Teach
Push-
Button

Removable

Spring-Loaded

Connector

Input
Logic
Jumpers

S1

J2

J15

Out 1
Out 2
In 1
In 2
n. c.
Earth.
24 VDC
0 VDC

D16 LED

Pin Listings
The allocation of pins on the main connector, J2, is specified
below.

Table 6: J2 Pin Listings

The allocation of pins on the I/O extension PCB is described
below.

Table 7: J15 Pin Listings

LED Indicators
The following table describes LED status for LEDs D15 and D16
present on the extension PCB.

Table 8: Analog Board LED Descriptions

DIP Switch Settings
DIP switches 1 through 6 on the S1 DIP switch array are
configured for the various applications described below. If no
information is otherwise provided these DIP switches should
remain in the OFF position.

DIP switch 8 is used to reset default configuration.

Pin

Signal

Description

Remarks

1

0V DC

Power

2

+24V DC

Power

3

Ground

Ground

4

Not connected

Not connected

5

In 2

Not used

6

In 1

Not used

DIP switch S1 (3) = 0

Remote teach

DIP switch S1 (3) = 1

7

Out 2

Error

0V DC = error

24V DC = no error

8

Out 1

Light array interrupted

0V DC = interrupted

24V DC = not interrupted

Pin

Signal

Minimum

Maximum

1

I Out

4 mA

20 mA

2

0V DC

3

V Out

0V

10V

4

0V DC

LED

Description

Status

Meaning

D15

Teach Indicator

Off

Teach inactive

Flashing

Teach active

Orange

Last step of teach process

D16

Analog Output Status

Off

V_out = OFF (0V)

Flashing

Start up (ignore output), over

current, or error

Green

Brightness proportional to

analog output

Advertising