Wiring diagrams, Configuring the sensor, Photoelectric sensor – Rockwell Automation 42QA ColorSight Series 9000 Photoelectric Sensors User Manual

Page 10

Advertising
background image

10 ColorSight Series 9000 PHOTOSWITCH

R

Photoelectric Sensor

75027--031--01(A), November 1999

Wiring Diagrams

10--30V DC

Orange

Cable version wired with PNP outputs

Brown

Blue

White

Black

+

--

Load

Sensor

Diagnostic

Load

10--30V DC

Teach/Gate

Cable version wired with NPN outputs

1

5

3

4

2

+

--

Load

Sensor

Diagnostic

Load

10--30V DC

Teach/Gate

Micro QD wired with PNP outputs

Micro QD wired with NPN outputs

1

5
3

4

2

+

--

Load

Sensor

Diagnostic

Load

10--30V DC

Teach/Gate

Mini QD wired with PNP outputs

Mini QD wired with NPN outputs

Orange

Brown

Blue

White

Black

--

+

Load

Sensor

Diagnostic

Load

Teach/Gate

1

5

3

4

2

--

+

Load

Sensor

Diagnostic

Load

10--30V DC

Teach/Gate

1

5
3

4

2

--

+

Load

Sensor

Diagnostic

Load

10--30V DC

Teach/Gate

Configuring the Sensor

ColorSight can be configured to meet a wide variety of industrial

applications. Various levels of coarse and fine color discrimination can be

selected along with time delay, gating input, and remote learn options.

Before initial use, it will be necessary to configure the sensor for the

application at hand.
Using the table on page 6 as a reference, set the dip-switches on the

user interface to define the following operating parameters.
1. Set the output operation, S2

The sensor output may be activated upon either a match or no match

color condition. The principal is the same as a light or dark operate

condition in monochrome photoelectric sensors. The factory default

setting of dip switch S2 is (=) which activates the output upon a color

match condition. Move this switch to (≠) for the opposite effect.

2. Set the time delay, S3

In some high speed applications it may be desirable to “stretch” the

output signal to support slower PLCs. For this reason, ColorSight

provides the option of selecting a 50ms time delay. This delay may be

activated by moving dip-switch S3 to the (TD) position. The factory

default setting is (0).

3. Set the color match operating mode, S4

Not all applications will require the same level of color discrimination.

Therefore, ColorSight offers two distinctly different modes of operation:
1. Color Only: which measures proportions of the RGB values, and

Advertising