Troubleshooting – Rockwell Automation 42QA ColorSight Series 9000 Photoelectric Sensors User Manual

Page 15

Advertising
background image

ColorSight Series 9000 PHOTOSWITCH

R

Photoelectric Sensor

15

75027--031--01(A), November 1999

Troubleshooting

Green LED does not
illuminate

Ensure power is connected to the sensor.

Target cannot be
learned

Ensure fiber optic cables are securely
seated in sensor cavity.

Ensure emitter (blue) side of fiber optic
cable is inserted in the emitter cavity
(blue).

Ensure the fiber optic head is 27mm (plus
tolerance) over and perpendicular to the
target.

Ensure fiber optic cable is not damaged
by checking the spot size for intensity.

Ensure the target being sensed is not
directly over high-frequency fluorescent
lighting.

Targets with glossy surfaces may require
positioning the fiber optic cable head at an
angle to prevent interference from
reflections.

Target is learned but
color discrimination is
not consistent over time

Ensure target color, shape, and distance
to fiber optic LED are consistent. If target
surface is textured such as textiles or
lumber, ensure that the Average mode is
being used. Single operating mode is best

used for smooth surfaces such as metal
or glass.

Ensure the proper operating mode is
activated. Color only mode is intended for
targets with large contrast, i.e., blue vs.
red. Color Plus Intensity mode is best for
targets with little contrast, i.e., light red vs.

medium red. Ensure ambient temperature
is within operating temperature and
tolerance of the sensor.

Advertising