d. Contrast Check

Test Points are provided on the back cover of the control (see Figure 5,

Page 6) to determine if sufficient contrast exists between the mark and the

background for reliable operation. The test point contacts are made of nick-

el plated stainless steel and can be immersed in water or short circuited

without affecting the operation of the control.

To check contrast, set the control in the manual mode. Set the web station-

ary with the light spot of the control on the background. Using a DC volt-

meter (100K ohm/volt), connect the test probes to the test points. Note the

reading and repeat the measurement with the light spot centered on the

mark. If the difference between the two readings is in excess of 300 mV,

there is sufficient contrast for reliable operation.

Check the mark/background with both the green and red LEDs. Use the

LED that provides the maximum voltage difference. By making this con-

trast check, you can also determine the correct mounting angle (Figures 2,

3, and 4) by adjusting the scanning angle to obtain the maximum voltage

difference.

Led Light Source

Selection

BACK-

GROUND

COLOR

REGISTRATION MARK COLOR

WHITE

BLUE

GREEN

YELLOW

ORANGE

RED

BLACK

WHITE

RED

OR

GREEN

RED

RED

OR

GREEN

GREEN

GREEN

RED

OR

GREEN

BLUE

RED

OR

GREEN

RED

OR

GREEN

RED

OR

GREEN

RED

OR

GREEN

RED

RED

OR

GREEN

GREEN

RED

RED

OR

GREEN

RED

OR

GREEN

RED

OR

GREEN

RED

GREEN

YELLOW

RED

OR

GREEN

RED

OR

GREEN

RED

OR

GREEN

RED

OR

GREEN

GREEN

GREEN

ORANGE

GREEN

RED

OR

GREEN

RED

OR

GREEN

RED

OR

GREEN

GREEN

RED

RED

GREEN

RED

RED

GREEN

GREEN

RED

BLACK

RED

OR

GREEN

RED

OR

GREEN

GREEN

GREEN

RED

RED

FIGURE 8

Additional Features

(Continued)

Advertising