Installation Instructions

PowerFlex

®

DC Drive - Frame A Bimetal

Thermostat

What This Kit Includes

Bimetal Thermostat

Two screws

Wire leads with connector

Thermal grease

Static strap

Tools That You Need

Phillips

®

screwdriver

Flathead screwdriver

Phillips

®

is a registered trademark of Phillips Screw Company.

What You Need to Do

To install the Bimetal Thermostat:

❐ Step 1: Remove power from the drive
❐ Step 2: Remove the protective covers
❐ Step 3: Remove the Control EMI shield and Control board
❐ Step 4: Remove the Pulse Transformer and Switching Power Supply

boards

❐ Step 5: Remove the existing Bimetal Thermostat
❐ Step 6: Install the new Bimetal Thermostat
❐ Step 7; Install the Pulse Transformer board and Switching Power

Supply board

❐ Step 8: Install the Control EMI Shield and Control board
❐ Step 9: Replace the protective covers and document the change

ATTENTION: Only qualified personnel familiar with DC
drives and associated machinery should plan or implement the
installation, start-up and subsequent maintenance of the system.
Failure to comply may result in personal injury and/or equipment
damage.

ATTENTION: To avoid an electric shock hazard, ensure that
all power to the drive has been removed before performing the
following.

ATTENTION: This drive contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing or
repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with
static control procedures, reference A-B publication 8000-4.5.2,
“Guarding Against Electrostatic Damage” or any other
applicable ESD protection handbook.