Step 1: remove power from the drive, Step 2: remove the protective covers – Rockwell Automation 20P PowerFlex DC Drive - Frame A Bimetal Thermostat User Manual
Page 2

2
PowerFlex® DC Drive - Frame A Bimetal Thermostat
Step 1: Remove Power
from the Drive
1. Remove and lock-out all incoming power to the drive.
Step 2: Remove the
Protective Covers
1. Disconnect the DPI cable from the HIM assembly (if present).
2. Remove the screws that secure the bottom cover to the drive, then slide
the cover down and off the drive chassis.
ATTENTION: Remove power before making or breaking cable
connections. When you remove or insert a cable connector with
power applied, an electrical arc may occur. An electrical arc can
cause personal injury or property damage by:
•
sending an erroneous signal to your system’s field devices,
causing unintended machine motion
•
causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the
module and its mating connector. Worn contacts may create
electrical resistance.
L1
L2
L3
O
I
=
Disconnect DPI cable
Tightening torque:
1.5 N•m (13.3 lb•in)