Install components – Rockwell Automation PF700 Power Interface Board and SMPS Board Replacement - Frames 7, 8, 9, 10 User Manual
Page 15
 
Publication 20B-IN22B-EN-P — December 2009
15
Component Replacement Procedures
Chapter 2
3. Remove the two Power
Interface Board mounting 
star screws located at the 
upper right and lower left 
corners of the board.
4. Using your fingers or
needle-nose pliers, squeeze 
the wings of each of the nine 
(9) spacers and separate the 
Power Interface Board from 
the mounting plate.
5. Remove the Power Interface Board.
Install Components
1. Install the new Power Interface Board.
Tighten board screws to 1.7 N-m (15 lb.-in.)
2. Reconnect all wiring except the ribbon cable going from the Power
Interface Board (J1) to the Main Control Board (J2).
3. Reinstall the Main Control Panel Assembly.
Tighten sheet metal screws to 3.2 N-m (28 lb.-in.)
4. Reconnect the ribbon cable going from the Power Interface Board
(J1) to the Main Control Board (J2).
5. Replace all safety shields and enclosure covers before applying
power to the drive.
Screws
Frame 7 shown