Rockwell Automation 42G PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors User Manual

Page 8

Advertising
background image

8

Typical ON/OFF Timing Diffuse (Light Operate) Nonretriggerable

Target

ON/OFF

Timing: OFF Delay

Timing: ON Delay

Timing: ON/OFF Delay

ON DELAY

OFF DELAY

Typical One-Shot Timing Diffuse (Light Operate) Nonretriggerable

Target

One-Shot

Delayed One-Shot

T2

T1

T1 is adjusted via the off delay potentiometer with either a long (0--15sec) or short (0--1.5sec) dip switch setting.
T2 is adjusted via the on delay potentiometer with either a long (0--15sec) or short (0--1.5sec) dip switch setting.

Application Example
Product is coming down a conveyor, if the product is a white box, a kicker located 3 seconds down the conveyor is

activated to push the box down another conveyor. The kicker should extend and retract for 1 second. The sensor is a

42GTP--9000. In this application an ON and OFF delay is required. Set the first DIP switch (S1) to TD position. Switch

(S2) will be set to LT position. Switch (S3) will be set to L position for a 3 second delay. Switch (S4) will be set to the

S position. The delay will be adjusted by turning the ON delay pot clockwise until the proper delay time is set. The OFF

delay pot will be turned clockwise so to set the one second OFF delay.

Publication PN--158404

DIR 10000321004 Ver 01

August 2014

Printed in USA

Visit our web site at:

http://www.ab.rockwellautomation.com

PHOTOSWITCH

R

is a registered trademark of Allen-Bradley Company.

Valox

R

is a registered trademark of General Electric Company.

Advertising