Rockwell Automation 20GY PowerFlex 755 with OEM Liquid Cooling Frame 6 and 7 AC Drives User Manual
Page 4

Rockwell Automation Publication 20GY-IN001A-EN-P - June 2011
4
PowerFlex® 755 with OEM Liquid Cooling Frame 6 and 7 AC Drives
Figure 1 - IP00, NEMA/UL Open Type Frames 6 and 7 (Frame 6 Shown)
Dimensions are in millimeters and (inches).
Frame 6: M6 (#12) mounting hardware recommended.
Frame 7: M8 (5/16 in.) mounting hardware recommended.
G
E
F
D
C
6.4 (0.25)
14.5 (0.57)
A
B
ш6.5 (0.26)
ш14.5 (0.57)
Frame 6
Frame 7
8.5 (0.33)
25.0 (0.98)
ш8.5 (0.33)
ш16.0 (0.63)
134.0
(5.28)
9.5
(0.37)
23.3
(0.92)
Frame
A
B
C
D
E
F
G
Weight
kg (lb)
6
308.0
(12.13)
665.5
(26.20)
346.4
(13.64)
283.0
(11.14)
623.0
(24.53)
254.0
(10.00)
609.0
(23.98)
43.6
(96.0)
7
430.0
(16.93)
881.5
(34.70)
349.6
(13.76)
380.0
(14.96)
838.0
(32.99)
330.0
(12.99)
825.0
(32.48)
83.6
(184.0)
IMPORTANT
Always install mounting hardware in all four
corners of the mounting legs for stability.
Only install mounting hardware through the
top key holes to help insure the drive is
securely fastened to the mounting surface.
At the bottom of the mounting legs, either the
key holes or optional open mounting slots
may be used.
Frame 6 Bottom View
Frame 7 Bottom View
42.0
(1.65)
69.5
(2.74)
48.2
(1.90)
INLET OUTLET
INLET
OUTLET
67.7
(2.67)
55.1
(2.17)
52.8
(2.08)
INLET OUTLET
INLET
OUTLET