Connecting the Coolant
Source

Drive Coolant Connections

For locations of the coolant inlet and outlet connections, see

Figure 1 on page 4

,

Figure 2 on page 5

or

Figure 3 on page 6

.

Coolant connections for PowerFlex 755 with OEM Liquid Cooling Frame 6 and
7 AC drives are made using o-ring face seal connections which have a:

• 3/4-inch nominal size
• “-12” SAE dash size
• 1-1/16-12 UN/UNF-2B external thread size

The drive coolant connection is shown in

Figure 4

. Perform the following steps

to complete the connection.

1. Verify that the o-ring is properly seated on the male fitting.
2. Using a backup wrench on the drive fitting, tighten the swivel nut fitting to

a torque of 81 N•m (60 lb•ft).

Figure 4 - Drive Coolant Connection

Fitting with Face Seal

O-Ring

Backup Wrench

Swivel Nut

Advertising