Rockwell Automation 42DBS-5100 Background Suppression with Timing PHOTOSWITCH User Manual

Installation instructions photoswitch

Advertising
background image

1

INSTALLATION INSTRUCTIONS PHOTOSWITCH

BACKGROUND SUPPRESSION CONTROL WITH TIMING, BULLETIN 42DBS-5100

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PG-9000

BULLETIN NUMBER

OPERATING

MODE

VOLTAGE

SUPPLY

CURRENT

SUPPLY

OUTPUT CHARACTERISTIC

RESPONSE

TIME

SUPPRESSION POINT

ADJUSTMENT RANGE

TYPICAL SUPPRESSION QUALITY

PHOTOHEAD

POWERBASES

TYPE

RATING

LEAKAGE

(OFF STATE)

WHITE BACK-

GROUND

CONTROL OFF

BLACK

TARGET CON-

TROL ON

42DBS-5100

TIMING

10--30

VDC

40mA MAX

NPN & PNP

100mA AT

10--30 VDC

1A

5ms

2.5--12

(6.3cm--30.5cm)

2.5

(6.35cm)

4

(10.1cm)

6

(15.2cm)

8

(20.3cm)

10

(25.4cm)

12

(30.5cm)

2.3

(5.89cm)

3.9

(9.9cm)

5.8

(14.7cm)

7.7

(19.5cm)

9.5

(24.1cm)

10.5

(26.6cm)

42DTB-5000

42DCB-5000

SPECIFICATIONS:
Range Adjustment

Fine and Coarse

. . . . . . . . . . . . . . . . . . . . . . . .

Ambient Temperature Range

--40

o

F to 150

o

F (--40

o

C to 65

o

C)

. .

Relative Humidity

90%

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Turn on Pulse Suppression

Yes

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Reverse Polarity Protection

Yes

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Output Overload and Short Circuit Protection

Yes

. . . . . . . . . . .

Field of View

3

o

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Transmitting LED

Infrared, 880nm

. . . . . . . . . . . . . . . . . . . . . . . .

Margin and Alignment Indicator with 3 Indicating Modes

-- Red

Output Energized

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-- Green

2 X Margin

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

-- Flashing Green

Over Current

. . . . . . . . . . . . . . . . . . . . . . . . . .

Lens Material

Acrylic

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Operating Environment NEMA, 3, 4, 12, 13 and IP66 (IEC529)

.

Approvals

UL Listed and CSA Certified

. . . . . . . . . . . . . . . . . . . .

Housing Material

High impact chemically resistant VALOX

. . .

Cable Base

Supplied with 10 (3m) of 5 conductor, flexible,

. . . . .

vinyl-covered cable.

Termination

Supplied with #6/32 nickel plated brass

. . . . . . . . . .

pressure type materials

Timing Ranges

TIMING RANGE (SECONDS)

SHORT

LONG

On/Off Delay

0--1.5

0--15

On Delay

0--1.5

0--15

Off Delay

0--1.5

0--15

One Shot

0--1.5

0--15

Delayed One Shot

0--1.5

0--15

ACCESSORIES
Optional Mounting Assemblies

PART NUMBER

DESCRIPTION

60-1577

Armored Cable Adapter

60-1785

Universal Mounting Assembly

60-1748

Heavy Duty Mounting Assembly

60-1840

Right Angle Mirror

60-2014

Flexi-mount Mounting Assembly

60-2072

PHOTOcountSWITCH Totalizer

60-2083

Photoguard Heavy Duty Protection

60-2213

Conduit Mounting Adapter

60-2230

Limit Switch Type Mounting Assembly

Advertising