Terminal base cable base – Rockwell Automation 42DBS-5100 Background Suppression with Timing PHOTOSWITCH User Manual

Page 3

Advertising
background image

33

15. Select Light or Dark operate mode with switch.

16. Adjust for the desired delays with the On and Off timing pots.

17. Tighten the lockscrew after adjusting the sensing range. A slight

increase in sensing distance may occur. Typically .25 (.63cm) at

12 (30.5cm), .12 (30.5cm) at a 6 (15.2cm) and .062 (1.57cm)

at 3 (7.62cm), for both background and target. If necessary,

sensing range variation can be compensated for by adjusting to

11.75 (29.8cm) for a 12 (30.5cm) suppression point, 5.875

(14.9cm) for a 6 (15.2cm) suppression point, and 2.95

(7.46cm) for a 3 (7.62cm) suppression point. Repeat steps 5 and

6 to verify the range after the lockscrew is tightened.

APPLICATION PRECAUTIONS

To obtain the high sensitivity and sharp cut-off required in a back-

ground suppression control, two photodetectors are used. One detec-

tor senses objects in close, the other detector will sense further out.

If the further out signal (background) is greater than or equal to

the close in signal, the control remains Off, if the close signal is great-

er than the background signal, the control output will turn On.

This interdependence of the two photodetectors and overlapping

sensing areas require that the object being sensed passes by the sensor

in certain directions or false operation could occur. Therefore, an ob-

ject always should travel on an x-axis perpendicular with the control.

See figures below.

FIELD OF VIEW

OVERLAP

SUPPRESSION

POINT

FAR SENSING

AREA

OBJECT

TO BE

SUPPRESSED

Direction

of travel

Control

Top View

Suppression

Point

Both

sensing ranges

overlap

OBJECT

TO BE

SUPPRESSED

CLOSE SENSING

AREA

Direction

of travel

WRONG DIRECTION OF TRAVEL

CORRECT DIRECTION OF TRAVEL

INSTALLATION

The control must be securely mounted on a firm, stable surface or

support. A mounting which is subject to excessive vibration or shift-

ing may cause intermittent operation.

OUTLINE DIMENSIONS

QUICK

DISCONNECT

SCREW

1 17/16

(33.3)

1 5/16

(11.9)

15/32

(24.2)

61/64

(139.5)

5 33/64

2 HOLES

10--32 UNF

NPSM

1/2--14

(27.3)

1 5/64

(8.3)

21/64

(38.1)

1 1/2

(13.8)

35/64

(54.7)

2 5/32

(65.8)

2 19/32

(71.0)

2 51/64

(2.7)

7/64

(8.7)MIN.

1 1/32

(36.5)

TO REMOVE SCANNER

LED

INDICATOR

(54.7)

2 5/32

(36.5)

17/16

(19.4)

49/64

3 63/64

(101.2)

61/64

(24.2)

15/32

(11.9)

39/64

(15.4)

2 7/8

(73.0)

1/4-18

NPSM

10’ (3m)

CABLE

7/64

(2.7)

3/4

(19.0

)

21/64

(8.3)

1 1/2

(38.1)

2 5/32

(54.7)

1/4-18

NPSM

10-32 UNC

2 HOLES

1 5/64

(27.3)

TERMINAL BASE

CABLE BASE

(15.4)

39/64

Advertising