Rockwell Automation 20P PowerFlex DC Drive - Frame A Field SCR/Dual Diode Bridge Module User Manual

Page 12

Advertising
background image

12

PowerFlex® DC Drive - Frame A Field SCR/Dual Diode Bridge Module

Step 6: Install the New
Field SCR/Dual Diode
Bridge Module

Install the new Field SCR/Dual Diode Bridge module in reverse order of
removal as detailed in Step 5:

Remove the Existing Field SCR/Dual Diode

Bridge Module on page 11

.

1. Apply thermal grease to the bottom of the Field SCR/Dual Diode

Bridge module before securing it to the heatsink.

2. Verify that the field circuit wires are connected to the correct location

on the Field SCR/Dual Diode Bridge module.

Step 7: Install the Pulse
Transformer and Switching
Power Supply Boards

• Install the Pulse Transformer and Switching Power Supply boards in

reverse order of removal as detailed in Step 4:

Remove the Pulse

Transformer and Switching Power Supply Boards on page 6

.

Step 8: Install the Control
EMI Shield and Control
Board

• Install the Control EMI Shield and Control board in the reverse order of

removal as detailed in Step 3:

Remove the Control EMI Shield and

Control Board on page 5

.

ATTENTION: Thermal grease must be applied to the bottom
of the Field SCR/Dual Diode Bridge module before securing
them to the heatsink or damage to the drive may occur.

Blue wire from 2D1
on Field board

Red wire from 2C1
on Field board &
Thin Red Wire from
XP on Pulse
Transformer board

Black wire from
2V1 on Field board

Brown or Green wire
from 2U1 on Field board

Blue wire from XP on
Pulse Transformer board

Black wire from XP on
Pulse Transformer board

ATTENTION: Each gate lead cable must be connected to the
exact connector from which it was removed on the Pulse
Transformer circuit board or damage to the drive may occur.