Panel Mounting Using the Dimensional Drawing

Mount the Comms Kit to a panel using two M4 or #8
panhead screws (not included).

Figure 2

shows mounting

dimensions.

Figure 2 Panel Mounting Dimensions

Panel Mounting Procedure Using Comms Kit as a Template

The following procedure enables you to use the assembled
Comms Kit as a template for drilling holes in the panel.

1. Using the assembled Comms Kit as a template, carefully

mark the center of both holes on the panel.

2. Remove the Comms Kit to a clean location.

3. Drill and tap the mounting holes for the recommended

M4 or #8 panhead screws (not included).

4. Place the Comms Kit back on the panel, and check for

proper hole alignment.

5. Attach the Comms Kit to the panel using the mounting

screws.

DIN Rail Mounting

The Comms Kit can be mounted using these DIN rails:

• 35 x 7.5 mm (EN 50 022 - 35 x 7.5)

• 35 x 15 mm (EN 50 022 - 35 x 15)

Before mounting the Comms Kit on a DIN rail, open the
DIN rail latch. Press the DIN rail mounting area of the
Comms Kit against the DIN rail, and manually lock the DIN
rail latch (

Figure 3

).

Figure 3 DIN Rail Mounting

Electrical Connections

After the communication adapter is installed and the
Comms Kit is mounted, make all required electrical
connections. See

Figure 4

and its related table showing the

connectors and their connection procedures.

Figure 4 Connecting to the Comms Kit

96.3 mm

(3.79 in.)

85.3 mm

(3.36 in.)

Ø 4 mm

(0.16 in.)

PORT

MOD

NET A

NET B

!

ATTENTION: Risk of equipment damage,
injury or death exists. Unpredictable operation
may occur if you fail to verify that parameter
settings and switch settings are compatible with
your application. Verify that settings are
compatible with your application before applying
power to the drive.

Item Description

Connection Procedure

Network
Connector

Connection for the network. Insert the network
cable plug into the mating connector on the
communications adapter.

+ -