Step 6: install the emi shield and control board – Rockwell Automation 20P PowerFlex DC Drive - Frame C Field Snubber Circuit Board User Manual
Page 7
 
PowerFlex® DC Drive - Frame C Field Snubber Circuit Board
7
Step 4: Remove the 
Existing Field Snubber 
Circuit Board
Important: Mark all connections and wires before removal to avoid
incorrect wiring during reassembly.
1. Remove the cable from connector X3 on the Field Snubber board.
2. Remove the seven screws, washers and wire leads (connections 2V1,
2U1 and 2C1 and one unmarked) from the board and remove the board 
from the drive. 
Step 5: Install the New 
Field Snubber Circuit Board 
Install the new Field Snubber circuit board in reverse order of removal and 
detailed in Step 4: 
Remove the Existing Field Snubber Circuit Board on
•
Tightening torque for the screws connecting the Field Snubber board to 
the Field SCR and Dual Diode Modules is 2.5 - 4.0 Nm (22-35 lb.-in.).
•
Inspect the existing X3 and XFCD cables for burn marks, cracks or loose 
connectors. If necessary, replace the cables on the Field board with the 
new cables provided.
Step 6: Install the EMI 
Shield and Control Board
Install the EMI Shield and Control board in reverse order of removal as 
detailed in Step 3: 
Move the EMI Shield and Control Board on page 5
.
=
Remove screws 
and washers
Remove screws 
and washers
Remove cable