Rockwell Automation Publication 440G-UM001A-EN-P — November 2013

31

Specifications

Appendix A

Environmental

General

Protection

Certifications

See the Product Certification link at

http://

www.rockwellautomation.com/rockwellautomation/certification/

for

Declaration of Conformity, Certificates, and other certification details.

UL Listed Industrial Control Equipment, Certified for US and Canada
CE Marked for all applicable directives
C-Tick Marked
TÜV Certified for Functional Safety up to SIL 3 Category 4 for use in

safety applications up to and including SIL 3, in accordance with IEC
61508 and EN 62061, Performance Level “e” and Category 4 in
accordance with ISO 13849-1, both for guard positioning and for
lock monitoring according to EN/ISO 14119:2013.

Operating temperature [C (F)]

0…55º (+14…131º)

Storage temperature [(C (F)]

-25…75º (+13…167º)

Operating humidity

5…95%, relative

Enclosure ingress rating

NEMA 3, 4x, 12, 13, IP66, IP67, IP69K

Shock and vibration

IEC 68-2-27 30 g, 11 ms/IEC 68-2-6 10…55 Hz

Hygienic

ISO 14159:2004 and EN 1672-2005 (for part of
the machine defined as “food splash area”)

Washdown

Suitable for sodium hydroxide-based
washdown fluids

Radio frequency / EMC

IEC-60947-5-3, FCC-1 (Parts 18 & 15), R&TTE

Materials

ABS, locking bolt and mounting bracket 304
stainless steel

Weight switch/actuator

Switch 400 g, actuator 22 g,
actuator mounting bracket 60 g

Connection

Flying lead or pigtail with M12 8-pin QD
connector (stainless steel)

Short-circuit protection

Incorporated

Current limitation

Incorporated

Overload protection

Incorporated

Reverse polarity protection

Incorporated

Overvoltage protection

Incorporated (up to 60V max.)

Thermal shutdown/restart

Incorporated