6 Bulletin 700 Type RTC & RTCR Solid-State Relays
Figure 4 Remote Potentiometer Connections
Manual Actuator
Timer can be equipped with a manual actuator (Cat. No. 700–N7) which is
used to energize the initiate circuit (Terminal P) manually using a separate
voltage source, 24V and 120V AC/DC only. It can be easily installed in the
field.
Specifications
Table 2 Voltage and Power Requirements
Repeat Accuracy:
±
1% or
±
50 milliseconds at constant voltage and
temperature.
Maximum Available Leakage Currents: 240V – 2.4 mA RMS, 120V – 2.4
mA RMS, 24V – 10 mA RMS.
Reset Time: 25 milliseconds required.
Operating Mode: On-Delay and Off-Delay. For instructions, refer to “Setting
the Mode and Timing Range” on page 3.
Timing Ranges and Switch Positions – Types RTC and RTCR
120V AC or DC
240V AC or DC
AC Voltage 50/60 Hz
+10%, -15%
Total Power
Required
Initiate Terminal P
Power
Coil Code
24V AC
8VA
4VA
U24
110-120V AC
9VA
4VA
U1
220-240V AC
11VA
5VA
U2
DC Voltage
+10%, -20%
Total Power
Required
Initiate Terminal P
Power
Coil Code
24V DC
10 W
5 W
U24
120V DC
11 W
5 W
U1
240V DC
12 W
5 W
U2