Connections, Status/diagnostic led indicator, Connections status/diagnostic led indicator – Rockwell Automation 440G-TLSZR-L-GD2 Guard Locking Switch User Manual

Page 10

Advertising
background image

TLSZR/L-GD2

10

10000302608 Ver 00 July 2012

Connections

Status/Diagnostic LED Indicator

For Learn Process LED error codes, see page 12.

8-Pin Micro (M12)

Color Function

Pin

8-Pin Cordset
889D-F8AB-*
or cable version

White Aux 1

Brown 24V

DC+

2

Green Lock 3

Yellow Safety

B+

4

Grey Safety

A

5

Pink Safety

B

6

Blue Gnd

/

0V

7

Red Safety

A+

8

* Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.

Operating

Status/Diagnostic LED State

Meaning

Solid Green

Door/Guard closed and locked, safety outputs active.

Solid Red

Door/Guard not locked, safety outputs off.

Blinking Red

Unit failure. See Troubleshooting, below.

Blinking Green

Door/Guard closed and locked, no input signal.

Troubleshooting

Status/Diagnostic LED State

Status

Troubleshooting

Off

Not powered

N/A

Solid Green

OSSD on

N/A

Solid Red

OSSD not active

N/A

Blinking Green

Power up test
or
Safety inputs not present

Check 24V DC or OSSD inputs (yellow and red wire)

Blinking Red

1 Hz Flash: Recoverable fault
4 Hz Flash: Non-recoverable fault

Recoverable fault: Check OSSD. Outputs are not shorted to GND,
24V DC, or each other. Cycle power.

Non-recoverable fault: Cycle power.

2 24V DC+

1 Aux

7 0V

6 Safety B

3 Lock Command

8 Safety A+

4 Safety B+

5 Safety A

Advertising