Application wiring example, K1 k2 – Rockwell Automation 440G-TLSZR-L-GD2 Guard Locking Switch User Manual

Page 15

Advertising
background image

TLSZR/L-GD2

10000302608 Ver 00 July 2012

15

Application Wiring Example

A1

A2

DI

S11

S12

S21

S22

S34

13

23

14

24

0V*

Reset

E-Stop

K1

K2

L11

S32

S42

L12

0

1

2

3

4

5

6

7

8

LOGIC

A1

A2

L11

L12

EMD

X32

*Set for 30 second
OFF Delay (adjustable)

0

1

2

3

4

5

6

7

8

9

RANGE

1

2

3

4

5

6

7

8

9

10

TIME

*

*

Gry

Pnk

Brn

Yel

Red

Blu

Wht

Aux.

TLSZR-GD2

DI = 440R-D22R2

EMD =

440R-EM4R2D

Ratings
The safety function initiated by the E-Stop meets the safety performance
requirements of SIL CL3 per IEC 62061:2005 and has a Category 4 structure
that can be used in systems requiring Performance Levels up to PLe per ISO13829-1:2008.
This circuit executes Category 0 stops.

24V*

* Class 2 Power Source

M

K1

K2

External Switched
Stop/Start Circuit

L1 L2 L3

K3

Gate Release

Grn

K3

17

18

K1

K2