D-2 Technical Specifications
Environmental Specifications
Recommended Settings for RSLinx/DDE
Real-Time Data Performance
Non-Real-Time Data Performance
Operating Temperature
-40° C to +60° C
Storage Temperature
-40° C to +85° C
Humidity
5 to 95 percent, non–condensing
Vibration
Operational: 0.006 in. DA/1.0 G Sine, 10 to 500 Hz, 3 orthogonal axes.
Non–operational: 0.015 in. DA/2.5 G Sine, 10 to 500 Hz, 3 orthogonal axes.
Shock
Operational: 15 G, Half Sine, 11 ms duration, 3 orthogonal axes, 3 (+) and 3 (-) pulses/axes, 18
pulses total.
Non–operational: 30 G, Half Sine, 11 ms duration, 3 orthogonal axes, 3 (+) and 3 (-) pulses/axes,
18 pulses total.
Polling Rate
Refer to graphs below.
Communications Timeouts
15 seconds
Processor Type
SLC 5/03+
20
15
10
5
0
0
200
400
600
#DDE
Connections
Poll Rate (msec)
20
15
10
5
0
0
2000
4000
6000
#DDE
Connections
Poll Rate (msec)