A - bulletin 1333 options, 1332-mod-f remote operator station, Bulletin 1333 options – Rockwell Automation 1333 Drive, 3/4-5HP, 230-575V Series D User Manual
Page 104

A
Appendix
A-1
Bulletin 1333 Options
Using Bulletin 1332 and
Bulletin 1332 and 1333 Options can be used with Series D drives.
1333 Options with
Point-to-point interconnections and the required Series D parameter
Bulletin 1333 Series D Drives
settings are detailed below and on the following pages. Refer to the
individual option kit instructions for installation procedures and the
additional information required to setup each option.
Bulletin 1333 Series D
Control and Signal Wiring Terminal Block
1332ĆMODĆF
Remote Operator Station
1332ĆMODĆF
Remote Operator Station
Term 3
Term 10
Term 11
Term 3
Term 4
Term 5
Term 7
Term 8
Term 9
Term 11
Term 12
Term 13
Term 1
Term 2
Term 3
Term 7
Term 8
Term 6
Start/Stop and Forward/Reverse Control
To allow the 1333 Series D to accept 1332-MOD-F start/stop and
forward/reverse commands, Parameter 8 Local/Remote Control Enable
must be set to 1 or 3.
Speed Control
To allow the 1333 Series D to accept the 1332-MOD-F speed
potentiometer signal, Parameter 9 Local/Remote Speed Enable must be set
to 1, 2 or 3.