Unpacking modules, System mounting requirements – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 33

Advertising
background image

Publication 1394-5.0 — May 2000

Installing Your 1394 (applies to all systems)

2-3

Unpacking Modules

Each 1394 System module ships with the following:

•

One system module

•

One system terminator

•

One terminal operating tool (part number 1394-194)

•

One user manual (publication 1394-5.0)

•

One application program lock key (GMC and GMC Turbo only)

•

Mating power connectors (5 and 10 kW Series C only)

•

Cable shield grounding clamps (5, 10, and 22 kW Series C only)

Note: To determine the series of your module, refer to Figure P.1 in

the Preface.

Each 1394 Axis Module ships with the following:

•

One 1394 Axis module

•

TB1 and TB2 connectors

•

One 1394 Axis module information sheet (publication 1394-5.5)

Remove all packing material, wedges, and braces from within and
around the components. After unpacking, check the item(s)
nameplate catalog number against the purchase order. Refer to
Appendix D for more information on catalog numbers.

System Mounting Requirements

There are several things that you need to take into account when
preparing to mount the 1394:

•

The ambient temperature of the location in which you will install
the 1394 must not exceed 50° C (122° F).

•

You must install the panel on a flat, rigid, vertical surface that
won’t be subjected to shock, vibration, moisture, oil mist, dust, or
corrosive vapors.

•

You have to mount the system vertically.

•

You need to maintain minimum clearances (see Figure 2.1) for
proper airflow, easy module access, and proper cable bend radius.

Refer to Appendix A for mounting dimensions, power dissipation, and
environmental specifications for the 1394.