Rockwell Automation 1784-PM02AE-TP0 2 Axis Servo Card Termination Panel Installation Instructions User Manual

2 axis servo card termination panel, Installation instructions, Identifying termination panel components

Advertising
background image

1

Publication 1784-IN007A-EN-P - November 2000

Installation Instructions

2 Axis Servo Card Termination Panel

(Catalog Number 1784-PM02AE-TP0x)

The termination panel is used in conjunction with the 1784-PM02AE
card to facilitate the wiring of drives and encoders for use with the
card. Because the card is installed inside the PC computer cabinet it
would be difficult to access for wiring drives, encoders, etc. A
termination panel, mounted separately from the card, allows for easier
access to the two axis terminals.

Identifying Termination
Panel Components

The following diagram identifies the connection for the cable to the
PCI 2 Axis Servo Card and the connections for wiring two axes.

Figure 1 1784-PM02AE-TP0x Termination Panel

P1

The connection marked P1 is for the cable from the PCI 2 Axis Servo
card. It accepts a straight 68 way Mini D shielded plug with a spring
latch. This connection is where the 1 meter or 3 meter premade cable
attaches to connect the termination panel to the PCI card. The cable is
packaged with the termination panel and shares the same catalog
number 1784-PM02AE-TP0x where x represents the length of the
cable.

Figure 2 1784-PM02AE-TP0x Cable Connection

77.00 mm

113.00 mm Max

P2

P3

P4

P1

L1

P1

Advertising