Mounting the Termination
Panel
The termination panel mounts to a DIN rail using the mounting feet
on the back of the panel. The termination panel cable comes in two
lengths; 1 meter and 3 meters. Therefore the termination panel can be
mounted no more than 3 meters from the back of the PC containing
the PCI 2 Axis Servo Card.
Figure 5 DIN Rail Assembly for Termination Panel
Termination Panel Cable
The 1784-PM02AE card is connected to the termination panel via a
premade 34 pair, 28 AWG SCSI shielded cable. The cable is available
in lengths of 1 meter and 3 meters. The cable comes shipped with the
termination panel and its catalog number is tied to the termination
panel where the ending x stands for the cable length of either 1 meter
or 3 meters.
P3 & P4
Function
P3 & P4
Function
A0
DRVFLT
B0
+CHA
A1
Home Area
B1
-CHA
A2
Reg 1
B2
+CHB
A3
Reg 2
B3
-CHB
A4
OK
B4
+CHZ
A5
IN_COM
B5
-CHZ
A6
Enable+
B6
Screen
A7
Enable-
B7
+Out
A8
Encoder 0V
B8
-Out
A9
Chassis
B9
Encoder Pwr
45.00 mm
Mounting Feet
Termination
Panel