Connection diagrams for allenćbradley encoders – Rockwell Automation 1771-DE Absolute Encoder Module User Manual User Manual
Page 72

Appendix
E
EĆ1
Connection Diagrams for AllenĆBradley Encoders
Figures E.1 throug
h Figure E.3
show you how to connect several
Allen-Bradley encoders to the absolute encoder module:
Figure E.1
shows you how to connect a Bulletin 845A encoder, 0 to
359-count, 10-bit, BCD, single-ended output encoder.
Figure E.2
shows you how to connect a Bulletin 845A encoder, 0 to
255-count, 8-bit, Standard Gray, single-ended output encoder.
Figure E.3 sh
ows you the connections for a Bulletin 845C encoder, 0 to
359-count, 10-bit, BCD, single-ended output, latching encoder.
Follow these guidelines:
Make the wht/orn wire (pin V) an open connection.
The encoder counts up in a counterclockwise direction if you make the
wht/yel wire (pinQ) an open connection or if you connect it to +5V; if
you connect it to ground, the encoder counts up in a clockwise
direction.
Signal common wht/blk (pin W) and ground blk (pin X) are internally
connected on the encoder.
Jumper the unused most-significant-bit input terminals.
Connection Diagrams for
AllenĆBradley Encoders
0 to 359Ćcount, 10Ćbit, BCD,
SingleĆended Output