Specifications – Rockwell Automation 1792D-4B0LP INSTL INSTR ARMORBLOCK INPUT User Manual

Page 7

Advertising
background image

7

ArmorBlock LP2 4 Sinking Input Module

Publication 1792D-5.27- January 1999

For more information on indications see the Product Data publication
1792-2.1.

Specifications

Red
Blink
Solid

Connection Timed Out
Failed Communication: A duplicate node address exists or
module is at the wrong baud rate.

I/O Status Indicators

Function

Module Status Indicator

Point Indicator

Condition

Inputs

Green
Green

None
Yellow

No valid input
Valid input

4 Input Module - Cat. No. 1792D-4B0LP

Sinking Input Specifications

Max

Min

Inputs per block

4 - 3 wire or dry contact PNP devices

Sensor Source Current (per input)

50mA

-

On-state Voltage

25V dc

10V dc

On-state Current

10mA

2mA

Off-state Voltage

5Vdc

Off-state Current

1.5mA

General Specifications

Indicators

Network Status - red/green
Module Status - red/green
Point LED- yellow

Communication Rate

• 125Kbps @ 500 meters(1600 feet) for thick

cable, flat media length 375 meters (1230 feet)

• 250Kbps @ 200 meters(600 feet) for thick cable,

flat media length 150 meters (492 feet)

• 500Kbps @ 100 meters (330 feet) for thick

cable, flat media length 75 meters (246 feet)

DeviceNet Power Voltage
Current

25V dc

125mA (no sensors)

300mA (full load)

11V dc

Dimensions (assembled to base)
inches - (millimeters)

1.023H x 2.7w x 4.72D
(26)H x (68.5)W x (120)D