DeviceNet Seminar Installation Instructions

6

Publication 1787Ć5.5 - December 1995

These are the descriptions and DeviceNet node numbers of the
devices contained in the demo boxes.

An I/O chassis with a SLC 500 processor and
a 1747-SDN scanner.

Scanner node number = 00

A 1794-ADN Flex I/O adapter connected to an analog output
module and a discrete input module.

Adapter node number = 02

An SMP-3 solid-state overload relay connected to the DeviceNet
network via a 1203-GK5 communication module.

SMP-3 solid-state overload relay node number = 03

A 1305 ac drive

connected to the DeviceNet network via a

1203-GK5 communication module.

1305 ac drive node number = 04

A Series 9000 PHOTOSWITCH

photoeye.

Photoeye node number = 07

A DeviceLink discrete I/O connected to a limit switch.

DeviceLink discrete I/O node number = 10

A RediSTATION

operator interface.

RediSTATION operator interface node number = 15

DeviceNetManager software connected to the DeviceNet

network

via a 1770-KFD interface module

.

Software node number = 62

Describing the Hardware

The scanner is the DeviceNet

master coordinating all

communications to all devices on

the DeviceNet network.

This DeviceNet data is transferred to and from the

SLC 500 processor via block and discrete I/O

transfers. This data is then used in the SLC 500

ladder program to do the actual control logic.

Analog output channel 0 is

connected to a volt meter to

easily display the voltage output. Also a 4Ćposition

selector switch is connected to bits 0 Ć 3 of the

1794ĆIB16 discrete input module.

The SMPĆ3 solidĆstate overload relay

provides solidĆstate motor overcurrent

protection in addition to ground fault

protection, jam/stall protection, and

protection against damage caused by

phase loss conditions.

The 1305 ac drive provides drive

status and diagnostic data at the

local panel using the part of the

drive known as the Human

Interface Module or at a

supervisory control station using an optional

communication module.

The Series 9000 photoeye is designed

to withstand harsh environments.

The sensor for this lab is retroreflective.

The DeviceLink discrete I/O

connects single nonĆDeviceNet

dc source devices to the

DeviceNet network.

The RediSTATION operator interface

has a start button, stop button, and a

red light.

DeviceNetManager

software configures

software parameters of

DeviceNet devices

from multiple vendors

and performs network

diagnostic and troubleshooting.