MobileView Connection Cable 7
Publication 2727-IN004C-MU-P
Attaching Connection Cable for Left or Right-Hand Operation
You can attach the MobileView Connection Cable on the left or right side of the
terminal for either left or right-hand operation. To relocate the cable, simply grasp
the strain relief and/or the plug and slide off of mount with a rocking motion.
IMPORTANT
Make sure the K3, 11-pin female connector clicks completely into
the S19, Main Connector when plugged in. Ensure proper seating
of the K2, 8-pin RJ-45 jack into the S4, Ethernet Connector.
To avoid pinching the cable with the back cover, avoid laying
cable on top of the T-supports.
After routing the cable, secure the back cover to the terminal
with the 6 screws. Tighten screws to a torque of 4.42 in-lbs to
maintain IP54 degree protection.
S6
,
COM
-Mo
d
u
l
S6
,
CO
M
-M
o
dul
Attaching Cable on Right
Attaching Cable on Left
Main Connector (S19)
Main Connector (S19)
S4, Ethernet Connector
S4, Ethernet Connector
Connection Cable
Connection Cable
Avoid routing cable
over T-support.
Avoid routing cable
over T-support.