Rockwell Automation 2727-MRT5_10_15_20 MobileView Connection Cable Installation Instructions User Manual

Page 7

Advertising
background image

MobileView Connection Cable 7

Publication 2727-IN004C-MU-P

Attaching Connection Cable for Left or Right-Hand Operation

You can attach the MobileView Connection Cable on the left or right side of the
terminal for either left or right-hand operation. To relocate the cable, simply grasp
the strain relief and/or the plug and slide off of mount with a rocking motion.

IMPORTANT

Make sure the K3, 11-pin female connector clicks completely into
the S19, Main Connector when plugged in. Ensure proper seating
of the K2, 8-pin RJ-45 jack into the S4, Ethernet Connector.

To avoid pinching the cable with the back cover, avoid laying
cable on top of the T-supports.

After routing the cable, secure the back cover to the terminal
with the 6 screws. Tighten screws to a torque of 4.42 in-lbs to
maintain IP54 degree protection.

S6

,

COM

-Mo

d

u

l

S6

,

CO

M

-M

o

dul

Attaching Cable on Right

Attaching Cable on Left

Main Connector (S19)

Main Connector (S19)

S4, Ethernet Connector

S4, Ethernet Connector

Connection Cable

Connection Cable

Avoid routing cable
over T-support.

Avoid routing cable
over T-support.