Attach the Adapter Plates to the Panel
1. The studs on the front adapter plate fit within the existing cutout of the
terminal.
2. Place the front adapter plate into the panel cutout until the sealing gasket
material is firmly against the front of the panel.
3. Mount the rear adapter plate to the front adapter plate studs from the back
of the panel (flat side of rear adapter plate towards front of enclosure).
Using the supplied nuts and lock washers, fasten the rear adapter plate to the studs of
the front adapter plate.
4. Using the torque wrench, tighten the nuts to no more than 1.36 N•m
(12 in-lb) to maintain a NEMA Type 4X rating. Do not overtighten.
Front Adapter Plate
Rear Adapter Plate
Clamp
Front of Panel or Enclosure
Nut and Washer
Inside of Panel or Enclosure