Industrial 20.1" Flat Panel Monitor

23

Publication 6185-5.2

To turn off the monitor without turning off the power:

1.

Press and hold both buttons for 2 seconds, until the monitor’s
backlight is turned OFF.

2.

Press either button to turn the backlight back ON.

Table D
Interpreting the Dimmer LED

Green LED

Amber LED

Condition

On

Off

Normal Operation - The monitor is receiving a valid video signal.

Off

On

Signal Not Received - The monitor is not receiving a valid video signal.

On (blinking
slowly)

Off

Backlight Off - The monitor is still ON but the backlight is powered OFF. Hold
down both buttons for 2 seconds to disable the backlight. Press either button to
enable the backlight.

On (blinking
fast then slow)

Off

Changing Dimmer Setting - When you are pressing one of the dimmer buttons,
the LED blinks fast and slows down as you reach the end of the possible dimmer
adjustments in that direction. The light stops blinking when you stop pressing
the button, and the amber LED blinks twice when the change has been saved.
Once a dimmer setting has been saved, it will be used each time the monitor is
powered ON.

On

On (blinking
slowly)

Calibration Mode - The monitor has a calibration mode to compensate for
abnormal signal levels. Calibration mode is started by holding down both buttons
for 8 seconds. To turn off the calibration mode, hold down both buttons for 2
seconds until the amber light is turned OFF. The amber light will blink twice after
calibration mode to indicate that the calibration is complete.

If you need to adjust the calibration mode, contact Rockwell Automation. These
instructions are provided only so you can get out of calibration mode if you get
into it accidentally.