Mounting clearance requirements – Rockwell Automation 6180P-xxxx Integrated Display Computers with Keypad User Manual User Manual
Page 20
Advertising
20
Rockwell Automation Publication 6180P-UM001C-EN-P - February 2014
Chapter 2
Installation
Mounting Clearance
Requirements
Figure 6 - Minimum Clearances
IMPORTANT
Because of self-heating, do not operate the computer in an enclosure with the
minimum clearances unless adequate ventilation or other cooling methods are
used to lower the temperature within the enclosure.
Allow enough clearance to easily install or remove peripheral components, such
as internal drives.
1
2
3
4
5
Item
Description
Value
1
Top
50 mm (2 in.)
2
Left
50 mm (2 in.)
3
Rear
Air flow
ODD
HDD access
25 mm (1 in.)
140 mm (5.5 in.)
178 mm (7 in.)
4
Right
I/O port access and
ventilation
76.2 mm (3 in.)
5
Bottom
102 mm (4 in.)
Right and left are based on facing the front of the
computer.