Rack mounting, bulletin 6154 – Rockwell Automation 6153 Industrial Computers (6153, 6154) User Manual

Page 12

Advertising
background image

Bulletin 6153 and 6154 Industrial Computers with Integrated CRT

12

Publication 6153-2.0

Rack Mounting, Bulletin 6154

The 6154 Industrial Computer can be installed in a rack cabinet that
conforms to EIA standards for equipment with 19” wide panels. The
cabinet must be tall enough to accommodate the computer’s height
and deep enough to accommodate the unit’s depth, while providing
rear clearance for cabling and air flow. A cabinet with a depth of 61
cm. (24 in.) is sufficient.

Note: The computer is not designed to be supported by the cabinet’s
front panel. Use either rack mount slides or a shelf to support the
weight of the unit.

To install a Bulletin 6154 computer in your rack:

1. Refer to the physical dimension drawings for your unit to confirm

that there is adequate space behind the panel where the unit is to
be mounted. Remember to allow extra space for air circulation.

Bulletin 6154 with 4 slots, Figure 3 on Page 6.

Bulletin 6154 with 8/12 slots, Figure 4 on Page 7.

2. Carefully remove the Industrial Computer from its packaging.

3. Attach the rack slides to the unit, and align to the mating slide

inside the cabinet.

4. Insert the computer in the rack cabinet from the front of the

cabinet. The pair(s) of holes in the lower part of the front panel
should align with the holes in the front rack rails.

Tip: It will be easier to install the computer if you support it with
a shelf or other support adjusted to the appropriate height.

5. Remove the protective adhesive sheet from the screen of the

Industrial Computer. The sheet is designed to prevent scratching
of the screen or the optional touchscreen during shipping and
installation. It should be removed before use.