8 Kinetix 2000 Shunt Module
Publication 2093-IN002A-
MU-P - December 2006
Shunt Module Connector Data
The internal shunt resistor (15 Ohm, 50 W) is the default setting for the shunt module.
Jumpers are factory installed from TS-1 to TS-2 and from RC-1 to RC-2 to make this default
selection.
Connectors on the shunt module are supplied with removable wiring plugs.
Shunt Module Connectors and Pinouts
Shunt Module Connectors and Indicators
Designator Description
Connector
Pin
Signal
TS
External passive shunt module
thermal switch connections
Two position
connector housing
1
TS1
(1)
(1)
Jumper is factory installed between these TS pins to select the internal thermal switch.
2 TS2
RC
External resistor connection
Three-position
connector housing
1
DC+
Internal shunt connection
2
INT
External collector connection
3
COL
(2)
(2)
Jumper is factory installed between these RC pins to select the internal shunt resistor.
DC+
INT
COL
TS1
TS2
Shunt Module, Front View
(2093-ASP06)
External Thermostat
(TS) Connector
External Shunt Resistor
(RC) Connector
Power Fault LED
Over-temp Fault LED
Bus Status LED