Motor overload protection – Rockwell Automation 2071-Axx Kinetix 3 Component Servo Drive User Manual
Page 18
 
18 Kinetix 3 Component Servo Drives
Publication 2071-IN001E-EN-P - August 2014
Motor Overload Protection
This servo drive uses solid-state motor overload protection that operates in accordance with 
UL 508C. Motor overload protection algorithms (thermal memory) that predict actual motor 
temperature that is based on operating conditions as long as control power is continuously 
applied. However, when control power is removed, thermal memory is not retained.
This drive also provides an input for an external temperature sensor or thermistor device, which 
is embedded in the motor, to support the UL requirement for motor overload protection.
The drive supports some motors that do not contain temperature sensors or thermistors; 
therefore, motor overload protection against excessive consecutive motor overloads followed by 
power-up is not supported.
This servo drive meets the following UL 508C requirements for solid-state overload protection.
See your servo drive user manual for the interconnect diagram that illustrates the wiring between 
your motor and drive.
Motor Overload Protection Trip Point
Value
Ultimately
100% overload
Within 8 minutes
200% overload
Within 20 seconds
600% overload
ATTENTION: Avoid overheat damage to your motor from excessive and successive motor 
overload faults by following the motor and drive-combination wiring diagram that is 
provided in the user manual.