Power wiring requirements, Shunt module power wiring requirements, Shunt module jumper settings – Rockwell Automation 2094-BSP2 Kinetix 6000 Shunt Module Installation Instructions User Manual

Page 8: Col int dc+ ts2 ts1

Advertising
background image

8 Kinetix 6000 Shunt Module

Publication 2094-IN004E-EN-P — June 2008

Power Wiring Requirements

Shunt Module Power Wiring Requirements

Using the default jumper settings, the Bulletin 2094 shunt module’s (200 W) internal
resistor is enabled and the thermal switch circuitry is not used. Remove the RC
connector jumper when wiring to a Bulletin 1394 external shunt module. Remove
the TS connector jumper when wiring to the 1394-SR36AF thermal-switch terminals.
Refer to the Kinetix Motion Control Selection Guide, publication

GMC-SG001

, for

Bulletin 1394 shunt module catalog numbers. Refer to the Kinetix 6000 Multi-axis
Servo Drive User Manual, publication

2094-UM001

, for interconnect diagrams.

Shunt Module Jumper Settings

(1)

These are the default jumper settings. Refer to External Shunt Modules Installation Instructions, publication

2090-IN004

,

when removing these jumpers and wiring to a Bulletin 1394 external shunt module.

IMPORTANT

The National Electrical Code and local electrical codes take precedence over
the values and methods provided.

Connections

Terminals

Recommended
Wire Size

mm

2

(AWG)

Torque Value
N•m (lb•in)

Pin

Signal

1394-SRxxxx

External passive shunt
module

RC-1

DC+

10 (8)

(1)

(1)

105 °C (221 °F), 600V.

1.2…1.5

(10.6…13.2)

RC-2

INT

RC-3

COL

Thermal switch

TS-1

TS1

0.75 (18)

0.22…0.25

(1.9…2.2)

TS-2

TS2

1 2 3

1 2

1 2 3

1 2

COL

INT

DC+

TS2
TS1

COL
INT
DC+

TS2
TS1

External Shunt Resistor

(RC) Connector

2094-BSP2 Shunt Module

(top view)

External Thermal Switch

(TS) Connector

Cable Shield

Clamp

Jumpers

(1)