3. Observe these restrictions on the flex zone and installation areas when installing the

cable:

The flex zone is the area in which the cable can repeatedly flex up to its specified
bend radius.

Installation areas require rigid mounting to prevent the cable from flexing where it
connects to other components.

4. Identify each connection on a cable by attaching a label around the outer insulation of

each wire adjacent to the drive connection.

5. Remove the O-ring on the motor receptacle when using a cable with a SpeedTec plug.

The type of plug on the cable determines whether an O-ring is required on the
receptacle.

IMPORTANT

The O-ring dampens the effects of vibration at the cable-to-motor connection.
This creates a more secure connection for a cable with a threaded plug.

U

Y

W

PE

WHITE

BLACK

MBRK+

MBRK-

Feature Offset
Minimum of 1x Cable Diameter

Flex Zone

2090-CPBM7DF-xxAFxx Shown

Installation Area
300 mm (12 in.)
approx.

Installation Area
300 mm (12 in.)
approx.

Exposed
Shields

SpeedTec Plug

Threaded Plug

Remove O-ring when mating with a
SpeedTec plug.

Install O-ring when mating with a
threaded plug.

O-ring in Groove

If an O-ring is installed, a SpeedTec plug will not engage with the receptacle.