Rockwell Automation 2090-CTHP8 Kinetix 6000M Hybrid Power Terminator Installation Instructions User Manual

Kinetix 6000m hybrid terminator, Installation instructions, About the hybrid terminator

Advertising
background image

Installation Instructions

Kinetix 6000M Hybrid Terminator

Catalog Number 2090-CTHP8

About the Hybrid Terminator

A Kinetix

® 6000M integrated drive-motor system shares DC bus and control power, system

status, and safety signals through a daisy-chain of hybrid cables between each integrated
drive-motor (IDM) in the drive system.

The 2090-CTHP8 hybrid terminator is a male M23 connector with a backshell cover that seals
the connector. The hybrid terminator is installed on the final IDM unit, as shown in the Kinetix
6000M Cable Routing Diagram d
iagram on

page 4

. It terminates the communication bus and

returns the IDM system status signal to the IDM power interface module (IPIM).

2090-CTHP8 Hybrid Terminator

Topic Page

Important User Information

2

Before You Begin

3

Installing the Hybrid Terminator

4

2090-CTHP8 Terminator Schematic and Pinout

5

Specifications 6

Additional Resources

6

Advertising