Install continuous-flex extension cables – Rockwell Automation 2090-CFxxx 2090-Series Motor/Actuator Cable Installation Instructions User Manual

Page 12

Advertising
background image

12

Rockwell Automation Publication 2090-IN050B-EN-P - July 2014

2090-Series Motor/Actuator Cables

2090-CFBM7DF-CDAF

xx feedback cables (-CD designation) include Hall

signal conductors and are designed for motors with incremental encoders.

Table 9 - Feedback Cable Pinouts (flying-leads with Hall signals)

Install Continuous-flex
Extension Cables

This figure illustrates how to measure the bend radius and where cable bends can
be made on continuous-flex extension cables.

Figure 5 - Continuous-flex Extension Cable Bend Radius Example

Feedback Cable Type

Cable Cat. No.

Description

Feedback cable
(continuous-flex)

2090-CFBM7DF-CDAF

xx

N/C

N/C

1
2
3
4
5
6
9

10
11
13
14
15
16
17

7
8

12

SIN+/AM+
SIN-/AM-
COS+/BM+
COS-/BM-
DATA+/IM+
DATA-/IM-
EPWR 5V
ECOM
EPWR 9V
TS+
TS-
S1
S2
S3
Spare
ABS
ECOM

N/C

1

2

3

4

5

16

15

14

13

12

11
10

9

8

7

6

17

Twisted Wire Pair

Motor Plug

Connector Backshell Shielded 360°

Wire Connection

To Drive

Shield

Connect Cable Shield to Ground

26 AWG Black

26 AWG White/Black
26 AWG Red
26 AWG White/Red

26 AWG Green
26 AWG White/Green

16 AWG Gray
16 AWG White/Gray
22 AWG Orange
22 AWG White/Orange
26 AWG Blue
26 AWG White/Blue

26 AWG Yellow

26 AWG White/Yellow
26 AWG Brown

26 AWG White/Brown

36 AWG Shield

B

B

D

Bend Area or

Continuous Flexing Area

2090-CPBM7E7-

xxAFxx cable is shown.

Continuous
Bend Radius

Cable

Diameter

Advertising