Install motor feedback cables – Rockwell Automation 2090-CFxxx 2090-Series Motor/Actuator Cable Installation Instructions User Manual

Page 9

Advertising
background image

Rockwell Automation Publication 2090-IN050B-EN-P - July 2014

9

2090-Series Motor/Actuator Cables

Install Motor Feedback Cables

This figure illustrates how to measure the bend radius and where cable bends can
be made on motor feedback cables.

Figure 4 - Motor Feedback Bend Radius Examples

Table 6 - Feedback Cable Specifications

2090-CFBM7DD-

xxxxxx

B

B

B

D

Bend Area or

Continuous Flexing Area

Bend Radius

Bend Radius

Cable

Diameter

Bend Radius

2090-CFBM7DF-

xxxxxx

Cable Type

Cable Cat. No.

D
mm (in.)

B

(1)

mm (in.)

(1) Dimension B (static bend radius) and continuous bend radius are based on the cable diameter. See Motor Power and Feedback Cable

Bend Radius Definitions on

page 5

for more information.

Continuous
Bend Radius

(1)

mm (in.)

Feedback cables
(standard, non-flex)

2090-CFBM7DD-CEAA

xx

9.8 (0.39)

68.6 (2.7)

N/A

2090-CFBM7DF-CEAA

xx

Feedback cables
(continuous-flex)

2090-CFBM7DD-CEAF

xx

10.3 (0.40)

72.1 (2.8)

124 (4.9)

2090-CFBM7DF-CEAF

xx

2090-CFBM7DF-CDAF

xx

11.7 (0.46)

81.9 (3.2)

140 (5.5)