Motor/actuator (m4 and m7) cable applications – Rockwell Automation 2090-CFxxx 2090-Series Motor/Actuator Cable Installation Instructions User Manual

Page 4

Advertising
background image

4

Rockwell Automation Publication 2090-IN050B-EN-P - July 2014

2090-Series Motor/Actuator Cables

Motor/Actuator (M4 and M7)
Cable Applications

Observe these guidelines when connecting your cable plug with the mating
motor connector, motor extension cable, or an extension cable receptacle:

Motors and actuators that are equipped with SpeedTec-ready DIN (M7)

connectors are compatible with threaded DIN (M4) cable plugs.

SpeedTec-ready DIN motor connectors are also compatible with SpeedTec

DIN (M7/E7) extension cable plugs.

Motors and actuators that are equipped with threaded DIN (M4)

connectors are compatible with only threaded DIN (M4) cable plugs.

Figure 2 - Motor/Actuator Connector and Cable Plug Compatibility

ATTENTION: The examples in this publication show all available connections.
Some connections are not used for specific installations. See your drive
installation instructions or user manual for recommended wire trim lengths and
wiring examples for your drive and motor application.

Do not connect unused wires. Trim and finish unused wires to help protect against
accidental contact with other wires or wire shields, or with a ground connection.

IMPORTANT

Standard (non-flex) cables can be bent or reformed during installation and
maintenance. Continuous-flex cables can be flexed repeatedly within a
specified bend radius when properly installed.

Do not use standard cables in a continuous-flex operation.

• Attach cable plug with one-quarter turn
• Receives M4 and M7 cable plugs

(O-ring is required for M4)

SpeedTec-ready

DIN Connectors

Threaded

DIN Connector

O-ring

SpeedTec DIN (M7) Cable Plug

Threaded DIN (M4) Cable Plug

• 2090-XXNFMF-S

xx (standard, non-flex) feedback cables

• 2090-CFBM4DF-CDAF

xx (continuous-flex) feedback cables

• 2090-XXNPMF-

xxSxx (standard, non-flex) power cables

• 2090-CPWM4DF-

xxAFxx (continuous-flex) power-only cables

• 2090-CPBM4DF-

xxAFxx (continuous-flex) power/brake cables

• Attach cable plug with 5…6 turns
• Receives only M4 cable plugs

• 2090-CFBM7DF-CEAA

xx (standard, non-flex) flying-lead, feedback cables

• 2090-CFBM7DD-CEAA

xx (standard, non-flex) drive-end connector, feedback cables

• 2090-CFBM7DF-CEAF

xx (continuous-flex) flying-lead, feedback cables

• 2090-CFBM7DD-CEAF

xx (continuous-flex) drive-end connector, feedback cables

• 2090-CFBM7DF-CDAF

xx (continuous-flex) flying-lead, feedback cables

• 2090-CPWM7DF-

xxAAxx (standard, non-flex) power-only cables

• 2090-CPBM7DF-

xxAAxx (standard, non-flex) power/brake cables

• 2090-CPWM7DF-

xxAFxx (continuous-flex) power-only cables

• 2090-CPBM7DF-

xxAFxx (continuous-flex) power/brake cables

• Attach cable plug with one-quarter turn
• Receives M4 and M7 cable plugs

(O-ring is required for M4)

• 3 m (9.8 ft) cable extensions
• Continuous-flex extension cables

Advertising