MobileView Machine Terminal MT750 15

Publication 2727-QS003E-MU-P

Ethernet Connection

The MobileView terminal is equipped with a 10Base-T interface which supports
TCP/IP protocol at 10MBaud for half-duplex communications.

The Ethernet connector at S3 on the Junction Box provides a connection to an
Ethernet network. The connector uses an 8-pin modular jack connector. Pinouts are
as follows:

Using the PC Card Slot

The PC card slot is a factory installed option and supports Type I, II, and III PC
cards. The following PC cards are available from Allen-Bradley. The terminal does
not support SRAM cards, Cardbus cards, or cards that use 12 volts for programming.

Pin #

Ethernet Signal

1

TD+

2

TD-

3

RD+

4

Not Used

5

Not Used

6

RD-

7

Not Used

8

Not Used

Catalog No.

Description

2711-NM28

8M flash ATA card for storing applications.

2711-NM216

16M flash ATA card for storing applications.

2711-NM232

32M flash ATA card for storing applications.

PC Card
Compartment