FM – Diameter Calculation

Drive Application Software – page 11 of 30

4.3 DiamPreset routine

The diameter preset routine is designed for applications where the diameter calculator will be
preset to one of several preset diameters or where a preset increase/decrease function is
required. If only a single diameter preset is required, this routine and the JSR instruction can
be deleted. If the DiamPreset routine is deleted, the (DiamCalc – In15 & In16) inputs
[yDiamPresetCmmd] & [yDiamPresetVal_in] must be controlled by the user’s custom
programming. If the diameter is not properly preset, the machine section may not be able to
regulate product tension in the process.

Input Parameters

Name

Type

Range

Description

1 Preset1Cmmd

BOOL

0 to 1

Preset diameter to Preset1Val_in

2 Preset2Cmmd

BOOL

0 to 1

Preset diameter to Preset2Val_in

3 Preset3Cmmd

BOOL

0 to 1

Preset diameter to Preset3Val_in

4 Preset1Val_in

REAL

0 to 500

Value of Preset 1

5 Preset2Val_in

REAL

0 to 500

Value of Preset 2

6 Preset3Val_in

REAL

0 to 500

Value of Preset 3

7 PresetIncCmmd

BOOL

0 to 1

Manual Diameter Increase

8 PresetDecCmmd

BOOL

0 to 1

Manual Diameter Decrease

9 PresetIncDecRate_inSec

REAL

0 to 10

Manual Diameter Increase/Decrease
Rate adjustment

Return Parameters

Name

Type

Range

Description

1 DiamPresetCmmd

BOOL

0 to 1

Diameter Preset Command to
DiamCalc routine

2 DiamPresetVal_in

REAL

0 to 500

Diameter Preset Value to DiamCalc
routine

4.3.1 Preset1Cmmd

This input is the command to the routine to select the Preset1Val_in as the output
DiamPresetVal_in. When this input is high and EnablePresets is high the
DiamPresetCmmd will be set high and the DiamPresetVal_in will be set equal to
Preset1Val_in.
Usage – Use this input to activate the value of Preset1Val_in as the preset input to
the DiamCalc routine.

4.3.2 Preset2Cmmd

This input is the command to the routine to select the Preset2Val_in as the output
DiamPresetVal_in. When this input is high and EnablePresets is high the
DiamPresetCmmd will be set high and the DiamPresetVal_in will be set equal to
Preset2Val_in.
Usage – Use this input to activate the Preset2Val_in as the preset value of the
DiamCalc routine.

4.3.3 Preset3Cmmd

This input is the command to the routine to select the Preset3Val_in as the output
DiamPresetVal_in. When this input is high and EnablePresets is high the
DiamPresetCmmd will be set high and the DiamPresetVal_in will be set equal to
Preset3Val_in.
Usage – Use this input to activate the Preset3Val_in as the preset value of the
DiamCalc routine.