9/440 Resolver–based CNC/Drive System
5A-34
The remote I/O circuitry and connector are integral parts of the wiring
board in the 9/440 resolver–based system module. In all Series, the remote
I/O connector is mounted on the 9/440 resolver–based control wiring
board. Figure 5A.22 shows this location.
Wire connections for the remote I/O communications are made through the
TB4 NODE ADAPT connector. Connect the wires for remote I/O as
shown in the following figure. Refer to your 1771 I/O documentation for
details on making remote I/O connections.
Figure 5A.22
Remote I/O Connector in System Module (All Series)
9/440 Resolver–based
System Module
Open Cover
TB4
RIO2
SHLD
RIO1
Remote I/O
Plug
Clear
Shield
Blue
9/440 Resolver–based Control Remote I/O LED
Assuming you have:
made all necessary remote I/O communication connections on your
1771 I/O network
configured your remote I/O port for the remote I/O network in AMP
written PAL to set $RMON true during the first PAL foreground
execution, and to handle input and output words ($RMI1 – $RMI8
inputs to PAL and $RMO1 – $RMO8 outputs from PAL.)
5A.4.2
9/440 Resolver–based
Control Remote I/O
Connection