Attach the adapter plate to the panel – Rockwell Automation 2711P-RAK4 Cutout Adapter Kit for PVPlus 400 Keypad and 600 TouchTerminals User Manual
Page 5
Advertising
![background image](/manuals/580592/5/background.png)
Cutout Adapter Kit 5
Publication 2711P-IN020A-MU-P
Attach the Adapter Plate to the Panel
1. Align the studs on the cutout adapter plate with the existing stud holes on
the front of the panel.
2. Place the adapter plate into the front of the panel cutout until the sealing
gasket material is firmly against the front of the panel.
3. Using the supplied nuts with lock washers, fasten the cutout plate onto the studs until
the sealing gasket is slightly compressed against the front of the panel.
4. Using the torque wrench, tighten the nuts to not more than 1.36 N•m
(12 in-lb) to maintain a NEMA Type 4X rating. Do not overtighten.
Front Adapter Plate
Nut and Washer
Inside of Panel or
Enclosure
Front of Panel or Enclosure
Advertising