4 200 Watt Passive Shunt Module

200 Watt Continuous Dissipation Cabinet Layout

Figure 2 details the proper position and cable separation for mounting
a drive with a shunt module inside a cabinet.

Figure 2
Typical Shunt Module Position and Conductor Routing for 200W Continuous
Dissipation

IMPORTANT

Only one passive shunt module can be used per
drive or damage to the drive will result.

87 mm (3.4 in.) minimum clearance
on all sides of the shunt module

Always separate low
voltage signal wiring
from high voltage power
wiring to reduce affects
of EMI.

Low voltage communications,

control I/O, and motor feedback cables

Shielded metal conduit, and
ferrite filters are also
recommended for reducing the
effects of EMI.

Twist conductors

(2 twists per

foot min.)

When shielding is used, the
shield must be grounded to the
shunt and drive as is the motor
power cable.

Motor power cable

AC power cable
Unshielded conductors