Attach the terminal to the adapter plate, 1000 keypad only – Rockwell Automation 2711P-xxxx Adapter Kit for PanelView Std and e Terminals User Manual

Page 7

Advertising
background image

Adapter Kit for PanelView Standard and PanelView “e” Terminal Cutouts 7

Publication 2711P-IN010C-MU-P - March 2007

1000 Keypad Only

The studs on the adapter plate fit within the cutout of the terminal.

1. Place the adapter plate into the panel cutout until the sealing gasket material

is firmly against the front of the panel.

2. Mount the adapter bar to the adapter plate studs from the back of the panel,

flat side of bar towards back of enclosure.

Use the 8 nuts and flat washers to fasten the adapter bar to the studs.

3. Using the torque wrench, tighten the nuts to no more than 1.13 Nm

(10 lb-in) to maintain a NEMA Type 4X rating.

Do not overtighten.

Attach the Terminal to the Adapter Plate

1. Insert the new terminal into the front of the enclosure until the terminal

gasket is flush with the adapter plate.

2. Install the mounting clips.

The number of clips varies depending on terminal type. The ends of the
mounting clips slide into the slots on the terminal.

Adapter Plate

Adapter Bars
with 4 Holes

Front of Panel or Enclosure

Inside of Panel or Enclosure

Nut and
Washer

Advertising