Dip switch test – Rockwell Automation 2707-M232P3_M485P3 DTAM Micro Operator Interface Module User Manual
Page 80

Chapter 8
Troubleshooting and Maintenance
8–6
Use the DIP switch test to verify the DIP switch positions.
To perform the DIP switch test:
1. Use the [NEXT] and [PREV] keys to display DIP Switch on the
test selection screen.
DTAM Micro Diag Test
Dipswitch
2. Press [
] to initiate the test.
The DTAM Micro displays the current DIP switch settings.
DIP Switch: 0 1 1 0 0 0
0 = OFF 1 = ON
DIP Switch
Position #1
DIP Switch
Position #6
The 6 positions of the DIP switch are shown in binary format (0 = Off, 1
= On). The leftmost value represents DIP switch position #1.
Note: Position #6 is always shown as 0 regardless of the setting. This
switch position is not used
3. Press any key to terminate the DIP switch test and display the next test
selection screen:
DTAM Micro Diag Test
Display Test
4. To terminate the test function , press the [NEXT] and [PREV] keys to
display Reset DUT in the test selection area. Press [
] to reset the
terminal.
DIP Switch Test