Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives Installation Instructions User Manual

Page 13

Advertising
background image

Kinetix 5500 Servo Drives 13

Rockwell Automation Publication 2198-IN001C-EN-P - January 2014

Kinetix 5500 Drive Power and I/O Wiring Requirements

Kinetix 5500 Drive
Cat. No.

Description

Connects to Terminals

Wire Size
mm

2

(AWG)

Strip Length
mm (in.)

Torque Value
N•m (lb•in)

Pin

Signal

2198-H003-ERS

x

2198-H008-ERS

x

2198-H015-ERS

x

2198-H025-ERS

x

2198-H040-ERS

x

Mains input
power

IPD-1
IPD-2
IPD-3
IPD-4

1.5…4
(16…12)

8.0 (0.31)

0.5…0.6
(4.4…5.3)

2198-H070-ERS

x

1.5…6
(16…10)

10.0 (0.39)

2198-H003-ERS

x

2198-H008-ERS

x

2198-H015-ERS

x

2198-H025-ERS

x

2198-H040-ERS

x

Motor power

MP-1
MP-2
MP-3
MP-4

Motor power
cable depends
on motor/drive
combination.
0.75…2.5

(1)

(18…14)

(1)

Building your own cables or using third-party cables is not an option. Use single motor cable catalog number 2090-CS

xM1DF-xxAAxx. Refer to the

Kinetix Motion Accessories Specifications Technical Data, publication

GMC-TD004

, for cable specifications.

8.0 (0.31)

0.5…0.6
(4.4…5.3)

2198-H070-ERS

x

2.5…6

(1)

(14…10)

10.0 (0.39)

2198-H

xxx-ERSx

PELV/SELV
24V power

CP-1
CP-2

24V+
24V-

2.5…0.5
(14…20)

7.0 (0.28)

0.22…0.25
(1.9…2.2)

Brake power

BC-1
BC-2

MBRK+
MBRK-

N/A

DC Bus power

DC-1
DC-2

DC+
DC-

N/A

(2)

N/A

(2)

(2)

DC bus connections are always made from drive-to-drive over the bus bar connection system. These terminals do not receive discrete wires.

N/A

(2)

Shunt power
(frames 2 and 3)

RC-1
RC-2

DC+
SH

4…0.5
(12…20)

8.0 (0.31)

0.5…0.6
(4.4…5.3)

Shunt power
(frame 1)

RC-1
RC-2

SH
DC+

Safety

(3)

(3)

These signals and the safe torque-off (STO) connector apply to only the 2198-H

xxx-ERS drives.

ST0-1
ST0-2
ST0-3
ST0-4
ST0-5

SB+
SB-
S1
SC
S2

1.5…0.2
(16…24)

10.0 (0.39)

N/A

(4)

(4)

This connector uses spring tension to hold wires in place.

Digital inputs

IOD-1
IOD-2
IOD-3
IOD-4

IN1

(5)

COM
IN2
SHLD

(5)

This signal has dual-functionality. You can use IN1 (IOD-1) as registration or Home input.

1.5…0.2
(16…24)

10.0 (0.39)

N/A

(4)

L1
L2
L3

W
V
U

Advertising